Vmax Imax Ihold Itrip Pd @25°C @25°C Max. Current Time Rimin R1max (Vdc) (A) (A) (A) (W) (A) (Sec) (W) (W) nSMD005 αZ 60.0 100 0.05 0.15 0.4 0.25 1.50 3.600 50.000 nSMD010 αN 60.0 100 0.10 0.25 0.4 0.50 1.00 1.600 15.000 nSMD012 αN 60.0 100 0.12 0.29 0.4 0.50 1.00 1.600 15.000 nSMD020 αA 24.0 100 0.20 0.46 0.6 8.00 0.08 0.350 2.700 nSMD025 αA 16.0 100 0.25 0.50 0.6 8.00 0.08 0.350 2.500 √ nSMD035 αB 6.0 100 0.35 0.75 0.6 8.00 0.10 0.250 1.300 √ nSMD050 αF 6.0 100 0.50 1.00 0.6 8.00 0.10 0.150 0.700 √ nSMD050-13.2V αF 13.2 100 0.50 1.00 0.6 8.00 0.10 0.150 0.700 √ nSMD075 αG 6.0 100 0.75 1.50 0.6 8.00 0.20 0.090 0.500 √ nSMD100 αH 6.0 100 1.00 1.80 0.6 8.00 0.30 0.055 0.270 √ √ nSMD110 αH 6.0 100 1.10 2.20 0.6 8.00 0.30 0.050 0.250 nSMD150 αI 6.0 100 1.50 3.00 0.8 8.00 0.30 0.040 0.130 √ nSMD200 αK 6.0 100 2.00 3.50 0.8 8.00 1.50 0.018 0.080 Ihold = Hold Current. Maximum current device will not trip in 25°C still air. Itrip = Trip Current. Minimum current at which the device will always trip in 25°C still air. Vmax = Maximum operating voltage device can withstand without damage at rated current (Imax). Imax = Maximum fault current device can withstand without damage at rated voltage (Vmax). Pd = Power dissipation when device is in the tripped state in 25°C still air environment at rated voltage. Rimin/max = Minimum/Maximum device resistance prior to tripping at 25°C. R1max = Maximum device resistance is measured one hour post reflow. CAUTION : Operation beyond the specified ratings may result in damage and possible arcing and flame.